          Mitech MG100 Portable LED View Film Lights

          Brand:

          Mitech

          Model:

          MG100

          Measuring range:

          Resolution Accuracy:

          Communication storage:

          Working time:

          Main unit weight:

          3.4kg

          Dimensions:

          464*76*177mm

          Package dimensions:

          58*17*27cm

          Total weight:

          4.7kg

          Product

          • Overview
          • Graphic
          • Technical
          • Configuration
          • Related

          Product

          • Overview
          • Graphic
          • Technical
          • Configuration
          • Related
          • Product Overview

            Mitech MG100 portable LED view film lights,can check the X-ray film one by one.With high-power LED light source, surface observation screen acrylic material, stable performance, strong structure, high uniformity, simple operation, user-friendly LED limit temperature, stepless dimming, can meet the needs better,which is widely used in X Ray detection for film observation and evaluation.It is the necessary professional precision testing equipment for improving production efficiency and saving production costs

            Function & application

            Quality control link of Metal processing manufacturing
            Quality control link of nonmetal manufacturing industry
            Teaching experiment of scientific research in Institutions of higher learning
            Quality inspection link of Quality inspection department


            Working Principle

            The principle of the LED view lamp is fixxing the film containing the image information on the observation screen, then the light emitted from the inner light source is scattered through the film through the observation screen to see if there is a defect on the film, and the sample is qualified according to the relevant standard

            Working Conditions

            Operation Temperature:040℃;
            Relative humidity:≤85%;
            In an environment free from corrosive medium;
            In an environment free from high magnetic field


            Instrument Features

            Widely used in the field of industrial testing and evaluation of radiation film negatives;

            Use high power LED light source, high brightness, uniformity is good;

            Compact design, durable, suitable for field mobility work;

            Use acrylic plate on the screen, good light transmission, diffuse scattering performance, durable;

            Can clearly observe the 5.0D above the black film on the small defects, which meet the daily needs;

            Limited color temperature within 6500K LED,do not hurt the eyes,Long time use is not easy to fatigue;

            Through the low-voltage electronic pulse width modulation, can achieve brightness stepless dimming, more to protect the

            safety of users;

            The use of advanced constant current drive, greatly extending the service life (up to 50,000 hours or more);

            With pedal mode and manual mode, to meet the different working habits, energy saving and environmental protection;

            Consistent with JB/T4730-2005Non-destructive testing of pressure equipment》、GB/T 19802-2005Industrial             radiography film filmand other relevant domestic and foreign standards

            Operating Method and Attentions

            Instrument Maintenance

            Read the manual carefully before using the instrument. Learn the operation steps and attentions to avoid damage the instrument or personal safety accidents caused by improper operation; 

            Do not block the LED view lamp vents, to avoid overheating the instrument, causing damage;

            When transport mobile LED view film lights, should avoid severe vibration, so as not to damage the internal devices;

            After using, please receive the shade, to prevent the loss of the shade, affecting the future use;

            When connection equipment, should be careful, moderate efforts, not to plug, hard pull;

            Do not disassemble the instrument.Any related matters of repair, please contact the Department of Mitech Instrument Services, 4000600280


          •  

          • Maximum brightness ≥400,000LUX
            The maximum blackness value can be observed ≥5.0D
            Uniformity coefficient g≥0.9
            Scattering coefficient ≥0.9
            Work 12 hours continuously of maximum brightness, the surface temperature rise ≤60℃
            Observation window 253mm*68mm
            Rated power 200W
            Power supply AC170~240V,47~63Hz
            Dimension 464*76*177mm
            Total Weight 3.4kg
          ×

          郵箱反饋

          如您在和我公司的交往中遇到問題,可通過以下方式和我們?nèi)〉寐?lián)系!
          您也可以撥打我們客戶服務(wù)熱線:400-0600-280

          *
          *

          MITECH CO. LTD

          TEL :

          86-10-58859527
          008613810243516

          ADD:

          E-506, 1# of ShangDi East Road, Haidian District, Beijing, China

          Email: 

          mvip@mitech-ndt.com

          公眾號
          亚洲国产初高中生女AV,超碰最新公开无码97,亚洲中文字幕无码一,亚洲精品无码专区
            <ul id="xt0w6"></ul>
            <cite id="xt0w6"><listing id="xt0w6"></listing></cite>
              <b id="xt0w6"><meter id="xt0w6"></meter></b>
            1. <thead id="xt0w6"></thead>
                  <form id="xt0w6"><meter id="xt0w6"></meter></form>